Laminar Air Flow Cabinet Horizontal Waiometra

BASIC MODEL
MICROPROCESSOR BASED LED + LCD CONTROLLER
Password protection, UV Tube & Front Door Interlocking, UV Tube life meter, HEPA Filter life meter & alarm

Principle

Waiometra Laminar Air Flow Cabinets are based on the principle to provide a work area completely bathed in a high efficiency perfect air, which is free from any kind of particulate contamination or impurities. Horizontal Laminar air flow are clean benches which have their own supply of highly purified air in which the total air present in the enclosure moves in a unidirection velocity flowing in parallel lines, which is free from macroscopic fluctuations. The horizontal laminar air flow units direct the air in mono direction which is away from the specimen and towards the user, giving ultimate protection to the product, which is susceptible to contamination induced by diffusion of contaminated air carrying air transported contaminants from the outside environment.

Laminar Air Flow Cabinet Horizontal
Microprocessor based LED + LCD Controller
Password protection (Programmable) for authorised operation
Initial self cleaning cycle with programmable time
Real time Cock
Display of life used & life remaining of HEPA filter and UV tube
HEPA filter alarm after HEPA filter life is over and guideline for further action through LCD controller
Audio Visual door unsafe alarm, if door is at incorrect operating height.
UV light/Door/Fluorescent Light Inter Lock i.e. UV switches ON only when door is closed, and automatically switches OFF fluorescent lights.
If UV light is ON & the operator tries to open the door, it raises audio visual alarm.
Display of safe / unsafe position of door
Energy Efficient Mechanism.
Low Noise and Vibration Levels.
Long Life and Low maintenance.
Conforms to US Federal Standard Class 100.
Modular Design (can be disassembled & assembled within 10 minutes at customer's sight.
Guaranteed supply of spares for 10 years.
Onsite installation and after sales service by company trained engineers.
Safety Features
M. C. B. is provided at the mains of the connection.
Fuses are provided on every electrical line to safeguard each and every component.

Waiometra laminar air flow cabinets are ideally suited in all the applications requiring protection of biological specimens or products from the possible contamination during the process or test. Waiometra laminar air flow bench is popular in pharmaceutical production, electronic industries and various other manufacturing applications.

Chemical
Medical
Food manufacturing
Food industry
Forensics
Microbiology and Tissue culture lab
Entomology
Veterinary and seed sciences
Direction of Flow Horizontal
Cleanliness Level Class 100
Velocity 70 cfm ±20%
Noise Level 65 db A ± 5%
Manometer Acrylic transparent manometer with Red Gel mounted on the front to show the differential pressure
Controller Microprocessor Controller with LCD display, menu control, automatic filter alarm system.
Working Table Made of perforated stainless steel sheet, stain finished.
Front Door Made of clear perpex sheet.
HEPA Filter
Media Glass Fiber Paper
Particle Retention 0.3 µm & above
Efficiency 99.97% at Hot DOP & 99.99% at Cold DOP
Pressure Drop 23mm WG
Pre Filter
Media Non woven synthetic Polyester with metallic wire mesh, pleated
Particle Retention 10-15 µm
Efficiency 90%
Pressure Drop 6mm WG
Blower Assembly Single phase,1440 rpm motor, directly coupled with a pair of metallic centrifugal impeller. Low noise & low vibration with dynamically balanced blower.
Ultra Violet Lamp Provided as per table below
Illumination Provided with diffusers as per table below
Standard Accessories Pressure manometer, Gas inlet nozzle, floor leveling screws & wire cord
Power Supply 220 V 50 Hz, Single Phase, AC supply
Construction Options
(i) Full body made of Mild Steel / G. I. Sheet duly powder coated (totally in white colour) with S. S. table top
(ii) Full body made of S. S. 304.
Construction

The Work Table is made of S. S. 304. Side panels and front door are made of thick plexiglass of special grade to resist the UV effect. Front door has a unique feature of double fold system. It can be half/full open during working. The entire unit rests on four castor wheels. The unit is completely modular & can be disassembled/assembled by the user within 10 minutes.

M.S./G.I. Stainless
Steel
Working Table
(in Mm)
Size of
Hepa Filter
No. of
Pre-filter
Details of
UV Tube
AMH-2 SSH-2 600x600x600
(2' x 2' x 2')
600x600x150
(2' x 2' x 6")
1 1 x 15 W
AMH-3 SSH-3 900x600x600
(3' x 2' x 2')
900x600x150
(3' x 2' x 6")
1 1 x 30 W
AMH-4 SSH-4 1200x600x600
(4' x 2' x 2')
1200x600x150
(4' x 2' x 6")
1 1 x 30 W
AMH-6 SSH-6 1800x600x600
(6' x 2' x 2')
900x600x150
(3' x 2' x 6")(x 2 filters)
2 1 x 30 W
AMH-8 SSH-8 2400x600x600
(8' x 2' x 2')
1200x600x150
(4' x 2' x 6")(x 2 filters)
2 2 x 30 W
(a) Megnehalic Gauge to track filter pressure
(b) IQ/OQ/PQ/DQ certificates
(c) Onsite Particle Counting Test with Air velocity & other tests.
ISO -9001:2008
ISO-14644-1
ISO-13485:2012
IEC 60601, EN 61326-1:2006
IEC 61010-1 Ed 3.0 & BS EN 12469:2000
CE Certificate
NSIC Regn. Certificate
SSI Regn. Certificate
Factory Testing Certificate for
(a) Particle Counting which prove the Class 100 working of the instruments (Optional
(b) Air velocity test certificate (Optional)
(c) Lighting intensity certificate.
IQ/OQ/PQ/DQ Certificates (Optional)