TurboCycler™ Thermal Cycler

High transparency, sensitive capacitive touchscreen, enables easy operation even with laboratory gloves on. Easy to understand, graphic-rich user interface, just plug, power on and go! User-friendly spinning wheel interface for temperature, time and cycle number adjustment. Built-in tools for Tm calculation, copy number conversion and mastermix preparation. The optional WiFi module allows you to monitor your experiment remotely.

Specications & Description
96 well, Gradient Block Compatible with regular profile or low profile 0.2 ml PCR tube, strip, none skirted, semi-skirted and fullskirted 96-well plate
Block Temperature
Block Temperature Range
4.0 to 99.9 °C
Max. Heating Rate ( °C/sec.) 5.5
Max. Cooling Rate ( °C/sec.) 3.3
Temperature Accuracy +/-0.3 °C
Temperature Uniformity Across Block +/-0.3 °C
Adjustable Ramping and Cooling Rate Yes, low /high
Gradient Temperature
Gradient Direction
Horizontal across the block
Gradient Temperature Range 30 ~ 99 °C
Gradient Temperature Difference Max. span 24 °C
Software Portability of Protocols Save and transfer to computer or additional cycler via USBflash drive
Stored Program No. > 500 sets
Registered User Folder No. 100 sets
User Folder Password Protection Yes
Run Status Report Yes, TXT output and transfer via USB flash drive
Tools TM calculator, Copy number calculator, Mastermix preparation calculator
General Display 7" color LCD with touch panel
Data Ports 1 USB A front port for USB flash drive
Heated Lid Yes, fixed 105 °C, 120 °C and off
Auto Restart after Power Outage Yes
Remote Motoring via WiFi Optional
Footprint Dimensions (H x W x D) 225 mm x 245 mm x 415 mm
Weight 10 kg
Power Supply VAC 100-240, 50/60 Hz, 700 W
Standard CE IVD, RoHS
CAT. NO. TCST9620
Turbo Cyler 2
Turbo Cyler 2
Turbo Cyler 2
Turbo Cyler 2
Turbo Cyler 2

Laboratory pH Meter MI150

pH/Temp combined bench meter with automatic calibration in 1 or 2 points with 7 selectable buffers, range -2.00 to 16.00 pH / -20.0 to 120.0°C, accuracy of ±0.01pH, automatic temperature compensation. Supplied with a pH refillable electrode MA917B/1, temperature probe MA831R, electrode holder MA9315, 12 VDC adapter and calibration solutions.

Turbo Cyler 2

Conductivity / Tds / Nacl / Temperature Meter Mi170

Combined logging with GLP EC/TDS/NaCl/Temp bench meter; range: EC 0.00 to 29.99 µS/cm; 30.0 to 299.0 µS/cm; 3 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; to 500.0 mS/cm without cat; TDS range 0.00 to 14.99 mg/L (ppm); 150 to 1499 mg/L (ppme); 1.50 to 14.99 g/L (ppt); 15.0 to 100 g/L (ppt); to 400.0 g/L; NaCl range 0 to 400%. Temp range: -9.9 to 120.0°C. 1 point calibration for EC with 6 memorized values. NaCl with 1 point. Supplied with MA814DB/1 probe, electrode holder MA9315, software Mi5200, RS232 connection with 2 meter cable, 12 VDC adapter and calibration solutions.

Turbo Cyler 2

Ph / Orp / Conductivity / Tds / Nacl / Temperature Meter Mi180

Combined logging with GLP pH/mV/EC/TDS/NaCl/Temp; pH range: -2.00 to 16.00 pH and -2.000 to 16.000 pH; ORP range: ±699,9 to ±2000 mV; EC range: 0.00 to 29.99 µS/cm; 30.0 to 299.0 µS/cm; 30.0 to 299.0 µS/cm; 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm; till 500.0 mS/cm without cat; TDS range: 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L; 150 to 1499 g/L (ppt); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L; till 400.0 g/L. Supplied with a pH refillable electrode MA917B/1, temperature probe MA831R and MA814DB/1 conductivity probe, electrode holder MA9315, software Mi5200, RS232 connection with 2 meter cable, 12 VDC adapter and calibration solutions.

Turbo Cyler 2

Dissolved Oxygen / Meter Mi190

Combined logging with GLP DO/Temp bench meter; range: DO: 0.00 to 45.00 mg/L (ppm) and 0.0 to 300.0%; Temp -5°C to 55.0°C. Resolution: 0.01 ppm to 0.1%, 0.1°C. Automatic calibration in one or two points at 0% (with MA9070 solution) or 100% (in air) of O2. Automatic altitude compensation 0 to 4000 m. Automatic salinity compensation 0 to 40 g/L. Automatic temperature compensation 0.0 to 50.0°C. Supplied complete with DO probe MA840, electrolyte solution MA9071S, 2 membranes, Mi5200 software, RS232 connection with 2 meter cable, 12 VDC adapter and calibration solution.

Turbo Cyler 2

Digital Brix Meter 0-85% Ma 871

Digital brix refractometer. Range 0-85% Brix, resolution 0.1%, accuracy ± 0.2%. Supplied with 9V battery and instruction manual.

Turbo Cyler 2